48.下列檢驗方法與診斷疾病之配對,何者錯誤?
(A)Platelet serotonin release assay:heparin-induced thrombocytopenia
(B)ADAMTS-13 assay:thrombotic thrombocytopenic purpura
(C)Platelet-associated IgG:immune thrombocytopenic purpura
(D)Platelet factor 4 antibody ELISA:anti-phospholipid syndrome
答案:登入後查看
統計: A(462), B(185), C(175), D(921), E(0) #3133895
統計: A(462), B(185), C(175), D(921), E(0) #3133895
詳解 (共 6 筆)
#6050113
Platelet serotonin release assay:heparin-induced thrombocytopenia
參考:https://www.ncbi.nlm.nih.gov/books/NBK482330/
4
0
#6157498
HIT:
- PF4 ELISA陽性→血清素釋放試驗做確認診斷
- 血清素釋放試驗陽性則確診HIT,若PF4 ELISA陽性但血清素釋放陰性也是排除HIT
ㅤㅤ
關於檢測HIT所使用的PF4 ELISA跟血清素釋放試驗(SRA):
ㅤㅤ
if the PF4 ELISA is positive, the result should be confirmed with the SRA, the gold standard test for confirming HIT with high sensitivity and specificity. Unlike ELISA, which detects the presence of antibodies, the SRA is a functional test, which detects the activation of platelets in the presence of antibodies. A donor platelet that becomes activated in the presence of heparin and a sample of the patient's blood (containing IgG) will release serotonin.
ㅤㅤ
A positive SRA confirms the diagnosis of HIT, and negative SRA rules out HIT, even in the setting of a positive ELISA.
ㅤㅤ
2
0
#6003481
dRVVT : anti-phospholipid syndrome
0
1